Computer Drive User Manual
C141-E078-02EN
4 - 6
(2) Limitation of side-mounting
Mount the side using the screw holes at both the ends as shown in Figure 4.5. Do not use the
center hole.
Figure 4.5 Limitation of side-mounting
(3) Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3
cm from the disk drive. At designing the system cabinet, consider following points.
• Make a suitable air flow so that the DE surface temperature does not exceed 55°C.
CAUTION
An air flow with an adequate wind velocity must be maintained to
deal with much heat generated from the MAC30xxFC.
Reference value: An air flow with a wind velocity of more than 0.5
m/s is required in an environment at 40°C, and
an air flow with a wind velocity of more than
1.0m/s in an environment at 45°C (Center of DE
cover ≤ 55°C).
• Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling
effect by measuring temperature of specific ICs and the DE. These measurement results
should be within a criteria listed in Table 4.1.