Computer Drive User Manual

C141-E078-02EN
4 - 6
(2) Limitation of side-mounting
Mount the side using the screw holes at both the ends as shown in Figure 4.5. Do not use the
center hole.
Figure 4.5 Limitation of side-mounting
(3) Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3
cm from the disk drive. At designing the system cabinet, consider following points.
Make a suitable air flow so that the DE surface temperature does not exceed 5C.
CAUTION
An air flow with an adequate wind velocity must be maintained to
deal with much heat generated from the MAC30xxFC.
Reference value: An air flow with a wind velocity of more than 0.5
m/s is required in an environment at 40°C, and
an air flow with a wind velocity of more than
1.0m/s in an environment at 45°C (Center of DE
cover 55°C).
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling
effect by measuring temperature of specific ICs and the DE. These measurement results
should be within a criteria listed in Table 4.1.
Holes for mounting screw
Use these holes (No. 1 to 4)
to mount.
Do not use these holes
2
1
3
4
Holes for
mounting
screw