Server User Manual
XSCF>
poweron -p 0
Note -
For a building block configuration, check the XSCF STANDBY LEDs of all the chassis
constituting the system.
Note -
For a building block configuration, switch the mode switches of the master chassis
and those chassis whose XSCFs are in the standby state.
XSCF>
showstatus
XSCF>
showhardconf
SPARC M 10-4S;
+ Serial:2081229003; Operator_Panel_Switch:Service;
+ System_Power:On; System_Phase:Cabinet Power On;
Partition#0 PPAR_Status:Running;
BB#00 Status:Normal; Role:Master; Ver:2050h; Serial:2081229003;
+ FRU-Part-Number:CA07361-D202 A0 ;
+ Power_Supply_System: ;
+ Memory_Size:320 GB;
Enter the PPAR-ID you noted in advance by using the showboards command.
In the following example, PPAR-ID 0 is specified.
6.4 Starting the Entire System
This section describes the procedure for starting the entire system.
The system can be started in either of the following two ways:
■
Starting the system with an XSCF command
■
Starting the system from the operation panel
1.
Check that the XSCF STANDBY LED on the operation panel is on.
2.
Log in to the XSCF shell.
3.
Switch the mode switch on the operation panel to Locked mode.
For details, see "2.2.2 Control function of the operation panel."
4.
Execute the showstatus command to confirm that there is no problem with
the FRU after the completion of maintenance.
If there is no problem, nothing is displayed.
5.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
・
December 201374