Server User Manual
XSCF>
showresult
0
XSCF>
showboards -a
PSB PPAR-ID(LSB) Assignment Pwr Conn Conf Test Fault
---- ------------ ----------- ---- ---- ---- ------- --------
00-000(00) AssignedyyyPassedNormal
01-000(01) AssignedyyyPassedNormal
#
ldm add-io PCIE8 domain01
#
ldm add-io PCIE9 domain01
#
ldm add-io PCIE10 domain01
#
ldm add-io PCIE11 domain01
#
ldm remove-io /BB1/PCI 0 domain01
(*1)
#
ldm add-io /BB1/PCI0 iodomain
(*1)
Note -
Start the root domain first, and then start I/O domains.
#
ldm start-domain domai n01
#
ldm start-domain iodom ain
4.
Execute the showboards command to confirm that the target chassis has
been incorporated into the physical partition.
The BB-ID of the chassis requiring maintenance is indicated by the system board
(PSB) number.
In the following example, [Fault] of PSB 01-0 displays "Normal", which indicates
that the system board is operating normally.
5.
If you performed maintenance on a PCIe card using dynamic reconfiguration
(DR), restore the devices that were released before the maintenance to their
original configurations.
Reassign the devices that were released from the root domain and I/O domains.
*1: PCIe slots are automatically assigned to the root domain. Therefore, to
reassign them to I/O domains, they must be released and then reassigned.
6.
Start the root domain and I/O domains.
If a virtual service is provided, the virtual service is automatically restarted.
7.
If there is a guest domain that uses a virtual device, log in to the guest domain
to restart the use of the device or incorporate it into the duplication function
again.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
・
December 201372