Waiting for BB#0 to enter install state.
[This operation may take up to 20 minute(s)]
(progress scale reported in seconds)
0..... 30.. done
Waiting for BB#0 to enter ready state.
[This operation may take up to 45 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... done
Do you want to start to diagnose BB#0?[s:start|c:cancel] :
s
Diagnostic tests for BB#0 have started.
Initial diagnosis is about to start, Continue?[y|n] :
y
SB#00-0 power on sequence started.
0..... 30..... 60....end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240.....|
270.....300.....330.....360..end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0..... 30..... 60..... 90.....120....end
SB powered off.
PSB Test Fault
---- -- ----- ------ --
00-0 Pa ssed Normal
done
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the replaced FRU.
FRU Stat us
------------------- --------------
/BB#0 Nor mal
------------------------------------------------------------------------------
The replacement of BB#0 has completed normally.[f:finish] :
f
2.
After confirming that the FRU to be diagnosed is displayed, enter "s".
3.
After confirming again that the FRU to be diagnosed is displayed, enter "y".
The following is displayed. Wait until the processing is complete.
4.
Confirm that the status is normal ("Normal") after diagnosis, and then enter
"f".
5.
When the maintenance menu appears, enter "c" to exit the operation.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual