Server User Manual

XSCF>
showstatus
XSCF>
showhardconf
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
XSCF>
showstatus
XSCF>
showhardconf
normally after the completion of maintenance.
3.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
4.
Close the rack door.
27.6.2 Active/Cold maintenance
1.
Connect all the power cords to the PSU backplane unit or power supply unit
of the chassis requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the XSCF DUAL control cable has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Execute the showstatus command to confirm that the XSCF DUAL control
cable is operating normally after the completion of maintenance.
4.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
5.
Close the rack door.
27.6.3 Inactive/Hot maintenance
1.
Return to the operation of the XSCF firmware replacefru command to confirm
that the XSCF DUAL control cable has been incorporated into the system.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual
December 2013422