Server User Manual

XSCF>
replacefru
XSCF>
showlogs error
XSCF>
replacefru
Note -
Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
before disconnecting them to ensure that they are reinstalled correctly.
XSCF>
showlogs error
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
27.3.2 Active/Cold maintenance
1.
Open the rack door.
2.
LogintotheXSCFshell.
3.
Execute the showlog s command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Execute the replacefru command to release the XSCF DUAL control cable
requiring maintenance from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
6.
Remove all the power cords from the PSU backplane unit or power supply
unit of the chassis requiring maintenance.
For details, see "5.5.2 Removing the power cord."
27.3.3 Inactive/Hot maintenance
1.
Open the rack door.
2.
LogintotheXSCFshell.
3.
Execute the showlog s command to identify the component requiring
maintenance.
Chapter 27 Maintaining the XSCF DUAL Control Cables 417