Caution -
To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
XSCF>
showlogs error
XSCF>
switchscf -t Standby
26.3 Enabling the Removal of an XSCF BB
Control Cable
This section describes preparations that must be completed prior to removing the
XSCF BB control cables. The preparation procedure differs depending on the
maintenance type as follows:
Active/Hot maintenance
Active/Cold maintenance
Inactive/Hot maintenance
Inactive/Cold maintenance
System-stopped maintenance
26.3.1 Active/Hot maintenance
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Execute the switchscf command to switch the master XSCF to a standby
XSCF.
Perform this when the chassis requiring maintenance is operating as a master
chassis.
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual
December 2013404