Server User Manual

Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
6.
Connect the two cables to the fan shelf.
7.
Install the low er cover and then secure it with the one screw.
8.
Install the upper cover.
9.
Slide the right and left stoppers of the upper cover outwards and then secure
the cover with the two screws.
22.5.2 Restoring the chassis
1.
Install all the fan units.
For details, see "19.5.1 Installing a fan unit."
2.
Install the front cover.
For details, see "6.5.3 Installing the front cover."
22.6 Restoring the System
This section describes the procedure for restoring the system after installing the fan
backplane.
1.
Connect all the power cords to the power supply unit of the crossbar box
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the fan backplane has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Pow er on all the physical partitions.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
4.
Close the rack door.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual
December 2013366