Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
Check the guide plate latch to ensure that the plate is securely installed.
4.
Support the fan shelf from below with one hand and then insert it carefully
into the chassis.
Arranging the cables in the center makes it easier to install the fan shelf.
5.
Tighten the three screws securing the fan shelf.
6.
Connect the two cables to the fan shelf.
7.
Install the low er cover and then secure it with the one screw.
8.
Install the upper cover.
9.
Slide the right and left stoppers of the upper cover outwards and then secure
the cover with the two screws.
10.
Install all the fan units.
For details, see "19.5 Installing a Fan Unit."
11.
Install the front cover.
For details, see "6.5.3 Installing the front cover."
12.
Reinstall the following components in their original positions in the order
shown.
- Power supply unit
For details, see "18.5 Installing a Power Supply Unit."
- Crossbar unit or crossbar filler unit
For details, see "16.5 Installing a Crossbar Unit."
- XSCF interface unit
For details, see "20.5 Installing the XSCF Interface Unit."
-XSCFunit
For details, see "17.5 Installing the XSCF Unit."
21.6 Restoring the System
This section describes the procedure for restoring the system after installing a
crossbar backplane unit.
1.
Connect all the power cords to the power supply unit of the crossbar box
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the crossbar backplane unit has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."