Server User Manual

XSCF>
showstatus
XSCF>
showhardconf
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
19.6.1 Active/Hot maintenance
1.
Return to the operation of the XSCF firmware replacefru command to confirm
that the fan unit has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2.
Execute the showstatus command to confirm that there is no problem with
the fan unit after the completion of maintenance.
3.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
4.
Close the rack door.
19.6.2 Inactive/Hot maintenance
1.
Return to the operation of the XSCF firmware replacefru command to confirm
that the fan unit has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2.
Pow er on the physical partition requiring maintenance.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
3.
Close the rack door.
19.6.3 System-stopped maintenance
1.
Connect all the power cords to the power supply unit of the crossbar box
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the fan unit has been incorporated into the system.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual