Server User Manual
XSCF>
showlogs error
XSCF>
replacefru
XSCF>
showlogs error
XSCF>
replacefru
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Power off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to release the pow er supply unit requiring
maintenance from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove the power cord from the pow er supply unit requiring maintenance.
For details, see "5.5.2 Removing the power cord."
18.3.3 System-stopped maintenance
1.
Open the rack door.
2.
LogintotheXSCFshell.
3.
Execute the showlog s command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Power off all the physical partitions.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to release the pow er supply unit requiring
maintenance from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7.
Remove all the power cords from the power supply unit of the crossbar box
Chapter 18 Maintaining the Po wer Supply Units of the Crossbar Box 321