Server User Manual

Note -
Reinstall the crossbar cables (optical) in their original positions by referring to the
notes that you made prior to the start of maintenance.
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
XSCF>
diagxbu -y -b 00 -p 02
3.
Connect all crossbar cables (optical) to the crossbar unit.
For details, see "25.5 Installing a Crossbar Cable (Optical)."
16.6 Restoring the System
This section describes the procedure for restoring the system after installing the
crossbar units. The restoration procedure differs depending on the maintenance type
as follows:
Active/Cold maintenance
Inactive/Cold maintenance
System-stopped maintenance
16.6.1 Active/Cold maintenance
1.
Connect all the power cords to the power supply unit of the crossbar box
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Execute the diagxbu command to diagnose the crossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is incorporated into the physical partition, and the physical
partition is powered on.
The example below specifies the following:
00: BB-ID of the chassis to start the diagnosis
02: PPAR-ID of the destination where the chassis to start the diagnosis is
connected (You can specify only one of these.)
3.
Pow er on the physical partition requiring maintenance.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
4.
Close the rack door.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual