Server User Manual
Note -
In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
Note -
Inactive/cold maintenance can be performed only for a building block configuration.
The inactive/cold maintenance procedure for a single-chassis configuration is the same as
that for stopping the system.
7.
Remove all the power cords from the PSU backplane unit of the chassis
requiring maintenance.
For details, see "5.5.2 Removing the power cord."
12.3.3 Inactive/Hot maintenance
For a single-chassis configuration
1.
Open the rack door.
2.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
3.
Stop the entire system.
For details, see "5.4 Stopping the Entire System."
For a building-block configuration
1.
Open the rack door.
2.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
3.
Pow er off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
12.3.4 Inactive/Cold maintenance
1.
Open the rack door.
2.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
3.
Pow er off the physical partition requiring maintenance.
For details, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
4.
Remove all the power cords from the PSU backplane unit of the chassis
requiring maintenance.
For details, see "5.5.2 Removing the power cord."
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual
・