Server User Manual
#
cfgadm -c unconfigure
Ap_ID
#
cfgadm -x led=fault,mode =blin k
Ap_ID
#
cfgadm -a
Note -
Use the DR of the system board on a physical partition for active/cold maintenance.
For the XCP and Oracle VM Server for SPARC/SRU versions that correspond to the DR, see
the latest Product Notes.
Note -
Active/cold maintenance can be performed only for a building block configuration.
XSCF>
showlogs error
XSCF>
replacefru
6.
Execute the cfgadm(1M) command to blink the CHECK LED of the internal
disk requiring maintenance, and determine its location.
Enter the Ap_ID you noted in advance.
7.
Execute the cfgadm(1M) command to confirm that the internal disk requiring
maintenance is disconnected.
The disconnected internal disk is displayed as "unconfigured."
12.3.2 Active/Cold maintenance
1.
Open the rack door.
2.
LogintotheXSCFshell.
3.
Execute the showlog s command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4.
Confirm the hardware and software configurations.
For details, see "4.2 Confirming the System Configuration."
5.
Release the chassis, in which the internal disk requiring maintenance is
mounted, from the physical partition.
For details, see "5.2 Releasing a Chassis from the Physical Partition."
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
Chapter 12 Maintaining the Internal Disks 229