Server User Manual
XSCF>
showstatus
XSCF>
showhardconf
Note -
Use the DR of the system board on a physical partition for active/cold maintenance.
For the XCP and Oracle VM Server for SPARC/SRU versions that correspond to the DR, see
the latest Product Notes.
Note -
Active/cold maintenance can be performed only for a building block configuration.
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
11.6.1 Active/Hot maintenance
1.
Return to the operation of the XSCF firmware replacefru command to confirm
that the fan unit has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2.
Execute the show status command to confirm that there is no problem with
the fan unit after the completion of maintenance.
3.
Execute the show hardconf command to check the hardware configuration
and the status of each component.
4.
Close the rack door.
11.6.2 Active/Cold maintenance
1.
Connect all the power cords to the PSU backplane unit of the chassis
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the chassis has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Incorporate the chassis, in which the fan unit requiring maintenance is
mounted, into the physical partition.
For details, see "6.2 Incorporating a Chassis into a Physical Partition."
4.
Close the rack door.
Chapter 11 Maintaining the Fan Units 215