Server User Manual
XSCF>
showlogs error
XSCF>
testsb -v -y -s 00-0
XSCF>
setpparparam -p 0 -s boo tscri pt "setenv auto-boot? fals e"
XSCF>
setpparmode -p 0 -m gues tboot =off
XSCF>
setpparmode -p 0 -m gues tboot =on
normally.
For details, see "3.3.5 Checking log information."
6.
Execute the testsb command to confirm that the CPU memory unit requiring
maintenance is normally recognized.
For a building block configuration, you do not have to execute the testsb
command. Proceed to step 7.
When you input optional "-y" for the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
The following example shows the diagnosis of system board 00-0.
7.
Execute the setpparparam command to deactivate the Autoboot function of
the control domain.
In the following example, PPAR-ID 0 is set for Auto boot.
8.
Execute the setpparmode command to deactivate the Autoboot function of
the guest domain.
In the following example, PPAR-ID 0 is set for Auto boot.
9.
Start the system.
For details, see "6.4.1 Starting the system with an XSCF command"or"6.4.2
Starting the system from the operation panel."
10.
The ok prompt appears.
11.
Enable the RAID volume to check the status.
For details, see "14.2.11 Re-enabling a hardware RAID volume" in the Fujitsu
M10/SPARC M10 Systems System Operation and Administration Guide.
12.
Execute the setpparmode command to activate the Autoboot function of the
guest domain.
In the following example, PPAR-ID 0 is set for Auto boot.
13.
Execute the showstatus command to confirm that the CPU memory unit is
operating normally after maintenance.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual
・
December 2013156