testsb -v -y -s 00-0
XSCF>
showstatus
XSCF>
showhardconf
XSCF>
showdate
XSCF>
setdate -s 102016592013. 00
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
7.
Execute the showstatus command to confirm that the CPU memory unit is
operating normally after maintenance.
If there is no problem, nothing is displayed.
8.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
Confirm that no asterisk (*) is displayed in front of each component.
9.
Execute the showdate command to confirm the XSCF time.
There is no need to set the time if the NTP server is set to the XSCF. Proceed to
step 11.
10.
If the XSCF time is different from the current time, execute the setdate
command to set the time.
Specify the time in either of the following formats:
yyyy.MM.DD-hh:mm:ss year.month.day-hour (24-hour clock):minute:second
MMDDhhmmyyyy.ss monthdayhour (24-hour clock) minuteyear.second
In the following example, "October 20, 2013 16:59:00" is specified.
11.
Start the system.
For details, see "6.4.1 Starting the system with an XSCF command"or"6.4.2
Starting the system from the operation panel."
12.
Close the rack door.
When the system is configured with a hardware RAID
1.
Connect all the power cords to the PSU backplane unit of the chassis
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual
・