Server User Manual

XSCF>
showlogs error
XSCF>
showstatus
XSCF>
showhardconf
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
For details, see "3.3.5 Checking log information."
5.
Switch the mode switches of the master chassis and those chassis whose
XSCFs are in the standby state to Locked mode.
-
For a building block configuration (without crossbar box)
Switch the mode switches of BB-ID#00 and #01 to Locked mode.
-
For a building block configuration (with crossbar box)
Switch the mode switches of BB-ID#80 and #81 to Locked mode.
6.
Execute the showstatus command to confirm that the CPU memory unit is
operating normally after maintenance.
If there is no problem, nothing is displayed.
7.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
Confirm that no asterisk (*) is displayed in front of each component.
8.
Start the system.
For details, see "6.4.1 Starting the system with an XSCF command"or"6.4.2
Starting the system from the operation panel."
9.
Close the rack door.
When the system is configured with a hardware RAID
1.
Connect all the power cords to the PSU backplane unit of the chassis
requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the chassis has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Execute the diagxbu command to diagnose the crossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M 10-4/SPARC M10-4S Service Manual