Datasheet
Data Sheet Fujitsu PRIMERGY TX200 S6 Server
Page 7 / 10 www.fujitsu.com/fts
Electrical values
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 9.5 - 4.0A
Rated current in basic conguration 1,3 0.6A
Active power (min. conguration) 111 W
Active power (max. conguration) 461 W
Active power note To estimate the power consumption of different congurations use the Power Calculator of the System Architect:
http://congurator.ts.fujitsu.com/public/
Apparent power (max. conguration) 490 VA
Heat emission 1659.6 kJ/h (1573.0 BTU/h)
Power Supply Notes In case of using an UPS we recommend to select a 1500VA/1000 W type as a minimum, because high power peaks
might be possible when switching over to battery!
The following Energy Star Familiy conguration options use less energy and reduce greenhouse gas emissions:
TX200 S6 E-StarFam1
http://ts.fujitsu.com/products/standard_servers/e_efcient.html
Compliance
Germany TÜV GS
Europe CE Class A *
USA/Canada CSAc/us
ULc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Japan VCCI Class A + JIS 61000-3-2
Australia/New Zealand C-Tick
Taiwan BSMI
Compliance notes There is general compliance with the safety requirements of all European countries and North America. National
approvals required in order to satisfy statutory regulations or for other reasons can be applied for on request.
* Warning:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
Compliance link https://sp.ts.fujitsu.com/sites/certicates/default.aspx