Data Sheet Fujitsu Server PRIMERGY RX200 S7 Dual socket 1U rack server
Page 6 / 9 www.fujitsu.com/fts
Server Management
Standard ServerView Suite - Deploy
SV Installation Manager
SV Scripting Toolkit
SV Deployment Manager (30-day trial version)
ServerView Suite - Control
SV Operations Manager incl. PDA and ASR & R
(Prefailure and Analysis; Automatic Server Recovery and Restart)
SV Performance Management
SV Power Management
SV RAID Manager
ServerView Suite - Maintain
SV Remote Management (iRMC)
SV Update Management (BIOS, Firmware, Windows Drives and SV Agents)
SV Asset Management
SV Online Diagnostics
ServerView Suite - Integrate
SV Integration packs e.g. for Microsoft System Center, Nagios, HP, SIM, HP NNM, IBM Tivoli, Altiris
Deployment Solutions and others
Option ServerView Suite - Deploy
SV Deployment Manager (full version)
ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Dynamize
SV Virtual-IO Manager (VIOM)
SV Resource Orchestrator Virtual Edition (ROR VE)
SV Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
SV Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding operating system dependencies for ServerView Suite software products see dedicated product data sheets.
Dimensions / Weight
Rack (W x D x H) 482 mm (Bezel) / 431mm (Body) x 762 mm x 43 mm
Mounting Depth Rack 718 mm
Height Unit Rack 1 U
19” rackmount Yes
Mounting Cable depth rack 200 mm (1000 mm Rack recommended)
Weight up to 18 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Operating ambient temperature 10 - 35 °C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation specication)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) Performance mode: 34 dB(A) min, 50 dB(A) max (idle) / 35 dB(A) min, 60 dB(A) max (operating)
Sound power (LWAd; 1B = 10dB) Performance mode: 5.1 B min , 6.7 B max (idle) / 5.1 B min, 7.6 B max (operating)
Noise notes Noise emissions and operation modes depend on system conguration.
Electrical values
Power supply conguration 1-2x 450W/800W hot-plug power supply
Max. output of single power supply 450/800 W (94% efciency)
Power supply efciency 94 % (80 PLUS platinum)
Hot-plug power supply output 450/800 W (94% efciency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 8.0 A (100 V) / 4.0 A (240 V)
Rated current in basic conguration 1.5 A (100 V) / 0.6 A (240 V)