Datasheet

Data Sheet Fujitsu Server PRIMERGY RX200 S7 Dual socket 1U rack server
Page 6 / 9 www.fujitsu.com/fts
Server Management
Standard ServerView Suite - Deploy
SV Installation Manager
SV Scripting Toolkit
SV Deployment Manager (30-day trial version)
ServerView Suite - Control
SV Operations Manager incl. PDA and ASR & R
(Prefailure and Analysis; Automatic Server Recovery and Restart)
SV Performance Management
SV Power Management
SV RAID Manager
ServerView Suite - Maintain
SV Remote Management (iRMC)
SV Update Management (BIOS, Firmware, Windows Drives and SV Agents)
SV Asset Management
SV Online Diagnostics
ServerView Suite - Integrate
SV Integration packs e.g. for Microsoft System Center, Nagios, HP, SIM, HP NNM, IBM Tivoli, Altiris
Deployment Solutions and others
Option ServerView Suite - Deploy
SV Deployment Manager (full version)
ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Dynamize
SV Virtual-IO Manager (VIOM)
SV Resource Orchestrator Virtual Edition (ROR VE)
SV Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
SV Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding operating system dependencies for ServerView Suite software products see dedicated product data sheets.
Dimensions / Weight
Rack (W x D x H) 482 mm (Bezel) / 431mm (Body) x 762 mm x 43 mm
Mounting Depth Rack 718 mm
Height Unit Rack 1 U
19” rackmount Yes
Mounting Cable depth rack 200 mm (1000 mm Rack recommended)
Weight up to 18 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Operating ambient temperature 10 - 35 °C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation specication)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) Performance mode: 34 dB(A) min, 50 dB(A) max (idle) / 35 dB(A) min, 60 dB(A) max (operating)
Sound power (LWAd; 1B = 10dB) Performance mode: 5.1 B min , 6.7 B max (idle) / 5.1 B min, 7.6 B max (operating)
Noise notes Noise emissions and operation modes depend on system conguration.
Electrical values
Power supply conguration 1-2x 450W/800W hot-plug power supply
Max. output of single power supply 450/800 W (94% efciency)
Power supply efciency 94 % (80 PLUS platinum)
Hot-plug power supply output 450/800 W (94% efciency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 8.0 A (100 V) / 4.0 A (240 V)
Rated current in basic conguration 1.5 A (100 V) / 0.6 A (240 V)