Datasheet

Data Sheet Fujitsu PRIMERGY RX100 S7 Mono socket 1 U rack server
Page 5 / 8 http://ts.fujitsu.com/Primergy
Operating system notes VMware ESX hints:
- SATA RAID is not supported
- Storing virtual machines locally requires a SAS RAID Controller
- Onboard GbE is supported on one of the two ports
Support of other Linux derivatives on demand
Server Management
Standard ASR&R Automatic Server Recovery and Restart
PDA Prefailure Detection and Anaylsis
Online update packages for BIOS, rmware drivers and ServerView Agents
ServerView Integration solutions for Microsoft SMS, MOM, SCOM, SCCM and Altiris
Deployment Solution ServerView Deployment Manager (fully functional 30-day trial version)
ServerView Deployment Manager (fully functional 30-day trial version)
Option iRMC S3 Advanced Pack
ServerView Integration for Tivoli TEC®, Tivoli NetView, HP NNM and HP Operations Manager
Server Management notes Regarding Operating System dependencies for ServerView Suite Software Products see dedicated Product Data sheets.
Dimensions / Weight
Rack (W x D x H) 482.6 mm (incl. quick release lever) / 431mm (Body) x 557 x 42.5 mm
Mounting Depth Rack 557 mm
Height Unit Rack 1 U
Mounting Cable depth rack 200 mm cable depth
Weight up to 14 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Sound pressure (LpAm) 24/30 dB(A) (min / max idle), 28.5 / 53.5 db(A) (min / max operating)
Sound power (LWAd; 1B = 10dB) 3.7/4.3 B (min / max idle), 4.2 / 6.8 B (min / max operating)
Noise notes / description May vary according to conguration
Operating ambient temperature 15 - 35°C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 Guideline for Data Center (installation locations)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Electrical values
Power supply conguration 1x standard power supply or1x hot-plug power supply or 2x hot plug power supplies for redundancy
Standard power supply output 300 W (90% efciency)
Hot-plug power supply output 450W (94% efciency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 127 V / 200 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 6A
Rated current in basic conguration 1.8 A / 0.8 A (100V / 240V)
Active power (max. conguration) 193 W
Apparent power (max. conguration) 195 VA
Heat emission 694.8 kJ/h (658.5 BTU/h)
Compliance
Germany GS
Europe CE Class A *
USA/Canada CSAc/us
ULc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)