Datasheet
Data Sheet FUJITSU Server PRIMERGY TX300 S7 Tower Server
Page 7 / 11 www.fujitsu.com/fts
Server Management
Option ServerView Suite - Deploy
SV Deployment Manager (full version)
ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Dynamize
SV Virtual-IO Manager (VIOM)
SV Resource Orchestrator Virtual Edition (ROR VE)
SV Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
SV Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding Operating System dependencies for ServerView Suite Software Products see dedicated Product Data sheets.
Dimensions / Weight
Floor-stand (W x D x H) 177 x 777 x 456 mm
Weight up to 35 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Operating ambient temperature 10 - 35 °C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation specication)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) Low noise mode:
Standard Fan Conguration: 32 dB(A) (idle) / 33 dB(A) (operating)
Redundant Fan Conguration: 33 dB(A) (idle) / 34 dB(A) (operating)
Sound power (LWAd; 1B = 10dB) Low noise mode:
Standard Fan Conguration: 5.0 B (idle) / 5.0 B (operating)
Redundant Fan Conguration: 5.1 B (idle) / 5.1 B (operating)
Noise notes Noise emissions and operation modes depend on system conguration.
Availability of the low noise mode depends on system conguration. To order an eligible system use the checkbox
“Enabling low noise mode” in System Architect.
Electrical values
Power supply conguration 1-4x 450 W/800 W hot-plug power supply
Hot-plug power supply output 450/800 W (94 % efciency, 80 PLUS platinum)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current in basic conguration 100 V - 240 V / TBD
Active power (max. conguration) 1070 W
Apparent power (max. conguration) 1080 VA
Heat emission 3852.0 kJ/h (3651.0 BTU/h)
Power Supply Notes Power Safeguard adapts system performance in case the wattage exceeds supply limits.
http://ts.fujitsu.com/products/standard_servers/e_efcient.html
Compliance
Germany GS
Europe CE Class A *
USA/Canada CSAc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Japan VCCI
China CCC (depending on conguration)