Datasheet
Data Sheet FUJITSU Server PRIMERGY RX300 S7 Dual socket 2U rack server
Page 7 / 11 www.fujitsu.com/fts
Server Management
Option ServerView Suite - Deploy
SV Deployment Manager (full version)
ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Dynamize
SV Virtual-IO Manager (VIOM)
SV Resource Orchestrator Virtual Edition (ROR VE)
SV Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
SV Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding Operating System dependencies for ServerView Suite software Products see dedicated Product Data sheets.
Dimensions / Weight
Rack (W x D x H) 482.6 mm (Bezel) / 445mm (Body) x 770 x 86.9 mm
Mounting Depth Rack 735 mm
Height Unit Rack 2 U
19” rackmount Yes
Weight up to 25 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Operating ambient temperature 10 - 35 °C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation specication)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) Low noise mode: 25 dB(A) min, 29 dB(A) max (idle) / 27 dB(A) min, 32 dB(A) max (operating)
Performance mode: 48 dB(A) (idle) / 48 dB(A) min, 68 dB(A) max (operating)
Sound power (LWAd; 1B = 10dB) Low noise mode: 4.1 B min, 4.5 max (idle) / 4.1 B min, 4.9 B max (operating)
Performance mode: 6.5 B (idle) / 6.5 B min, 8.2 B max (operating)
Noise notes Noise emissions and operation modes depend on system conguration.
Availability of the low noise mode depends on system conguration. To order an eligible system use the checkbox
“Enabling low noise mode” in System Architect.
Electrical values
Power supply conguration 1-2x 450W/800W hot-plug power supply
Max. output of single power supply 450/800 W (94% efciency)
Power supply efciency 94 % (80 PLUS platinum)
Hot-plug power supply output 450/800 W (94% efciency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 8.2 A (100 V) / 3.3 A (240 V)
Rated current in basic conguration 100 V - 240 V / TBD
Active power (min. conguration) 53 W
Active power (max. conguration) 830 W
Active power note To estimate the power consumption of different congurations use the Power Calculator of the System Architect:
http://congurator.ts.fujitsu.com/public/
Apparent power (max. conguration) 873 VA
Heat emission 2988.0 kJ/h (2832.1 BTU/h)
Power Supply Notes Power Safeguard adapts system performance in case the wattage exceeds supply limits.
Compliance
Germany GS
Europe CE Class A *