Datasheet
3
FTR-K1 SERIES
n COIL RATING
Coil
Code
Rated Coil
Voltage
(VDC)
Coil Resistance
+/- 10% (Ohm)
Must Operate
Voltage
(VDC) *
Must Release-
Voltage
(VDC) *
Max. Coil Voltage
(VDC)
Rated Power
(mW)
005 5 147 3.3 0.25 11.5
170
006 6 211 4 0.3 13.8
009 9 476 5.9 0.45 20.7
012 12 847 7.9 0.6 27.6
018 18 1,910 11.9 0.9 41.4
024 24 3,390 15.9 1.2 55.2
048 48 10,600 31.7 2.4 110.4 217
060 60 20,570 39.6 3 138 175
Type Compliance Contact rating
UL UL 508
E63614
Flammability: UL 94-V0 (plastics)
5A, 277 VAC (resistive)
5A, 30 VDC (resistive)
1/10 HP, 277VAC /125VAC
Pilot duty: D300, C300, R300, B300
CSA C22.2 No. 14
LR 40304
VDE
40006591
EN 61810-1 (VDE 0435-Part 201)
2004-07
250VAC; 6A / 30VDC; 6A :
- 10K ops. FTR-LY(A;P)A...(E;Y;V) -40 °C to +85 °C
- 5K ops. FTR-LY(C;R)A...(E;Y;V) -40 °C to +85 °C
EN 60730-1 (VDE 0631-Part 1) 250VAC; 6(1,5)A, 30K ops. : FTR-LY(A;P)A...(Y;V) +85 °C
250VAC; 3(1,5)A, 100K ops. : FTR-LY(A;P)A...(Y;V) +85 °C
EN 61984 (VDE 0627)
EN 60335-1 (VDE 0700-Part 1)
-
n SAFETY STANDARDS
FTR-LY SERIES
Note: All values in the table are valid for 20°C and zero contact current.
*Speciedoperatevaluesarevalidforpulsewavevoltage.