Datasheet
3
FTR-K1 SERIES
n COIL RATING
Coil
Code
Rated Coil
Voltage
(VDC)
Coil Resistance
+/- 10% (Ohm)
Must Operate
Voltage
(VDC) *
Must Release-
Voltage
(VDC) *
Max. Coil Voltage
(VDC)
Rated Power
(mW)
005 5 62 3.5 0.5 12.2
400
006 6 90 4.2 0.6 14.7
009 9 202 6.3 0.9 22
012 12 360 8.4 1.2 29.4
018 18 810 12.6 1.8 44.1
022 22 1,210 15.4 2.2 53.9
024 24 1,440 16.8 2.4 58.8
028 28 1,960 19.6 2.8 68.6
048 48 5,360 33.6 4.8 117.6 430
060 60 8,570 42.0 6.0 147.0
420
110 110 28,800 77.0 11.0 269.5
Note: All values in the table are valid for 20°C and zero contact current.
* Specied operate values are valid for pulse wave voltage.
Type Compliance Contact rating
UL UL 508
E63614
FTR-K1CK ( ) W FTR-K1AK ( ) T
Flammability: UL 94-V0 (plastics)
16A, 277VAC/24VDC (resistive)
20A, 277VAC (resistive)
1 HP, 277VAC
1/2 HP, 125VAC
1/8 HP, 125VAC
TV-5, 120VAC, 25,000 cycles
(only make contact)
Pilot duty: B300
16A, 24VAC (resistive)
16A, 277VAC (resistive)
20A, 277VAC (resistive)
1 HP, 277VAC
1/2 HP, 125VAC
TV-5, 120VAC 25,000 cycles
Pilot duty: A300
CSA C22.2 No. 14
LR 40304
VDE 0435, 0631, 0700, 0860,
40013848
16A, 250VAC (cosφ=1), 85˚C
3.5A, 250VAC (cosφ=0.4), 85˚C
16 A 24VDC (0ms), 85˚C
5A/80A, 250VAC 10,000 times, 85˚C (only make contact)
SEMKO EN 61058-1:1992 and A1
EN 61095:1993 and A1+A11
250VAC, 16 (3)A 40T85
5A/80A 250VAC 40T85 (only make contact)
n SAFETY STANDARDS
FTR-F4 SERIES
Complies with NEMKO, DEMKO, FIMKO
FTR-K1 SERIES