User guide

Chapter 2 Components
> 2.2 2.5" Type Controller Enclosure
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
61
Copyright 2010 FUJITSU LIMITED
P3AM-3042-06ENZ0
ETERNUS DX90 Fibre Channel model
Figure 2.17
shows the ETERNUS DX90 Fibre Channel model controller.
Figure 2.17 ETERNUS DX90 Fibre Channel model controller
System Capacitor Unit (SCU)
An SCU is installed in the controller as a backup power source in case of power outage.
MASTER LED
Glows green ( ) when the controller is set
as the Master CM.
UNIT READY/FAULT LED
Glows green ( ) during normal operation.
Glows orange ( ) during the post power on
initialization phase. Also glows orange ( ) to
indicate a fault has been detected.
FAULT LED
Glows orange ( ) when a fault has been detected
in the Fibre Channel port.
FC LINKUP LED
Glows green ( ) when link has been established.
SAS (DE) LINKUP LED
Glows green ( ) when link has been established.
SCU STATUS LED
Glows green ( ) when SCU is normal.
Blinks green ( ) when being charged
(for about one minute after the device power is turned on).
IDENTIFY LED
Blinks blue ( ) or turns off ( ) as ordered via GUI to identify the enclosure installation locations.
Fibre Channel ports (0, 1, 2, 3 from left)
Dual LC connectors for Fibre Channel cables.
SAS (OUT) port
Connector for a miniSAS cable
Used to connect the Controller Enclosure to a Drive Enclosure.
LAN port (1000Base-T/100Base-TX/10Base-T)
(RMT port (left), MNT port (right))
RJ45 connectors for LAN cables
Each controller has two such ports.
LINK LED
Glows green ( ) when link has been established.
ACT LED
Glows green ( ) when data is being sent and received.
PWC port
This is not used.
MPORTAN
If a power failure lasts for more than 20ms, the SCU starts supplying
power, and the controller's cache data is copied to flash memory.
There is no limit to the post-failure data retention time.
SCU failure will disable the cache function, leading to degraded
performance.