User guide

Chapter 9 Operation and Maintenance
> 9.4 Post Start-of-Operation Changes to the Configuration
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
205
Copyright 2010 FUJITSU LIMITED
P3AM-3042-06ENZ0
9.4.3 Replacing SAS Cards
The following explains how to replace a failed SAS card.
Note that this is only an overview of the replacement procedure. Refer to the relevant manuals
for more details.
The procedure to replace a SAS card is as follows:
Procedure
1 Before performing this procedure, use the ETERNUS DX60/DX80's GUI or CLI
to check the SAS address or host affinity of the SAS card that is to be replaced,
and record this setting for later replication.
2 Replace the server-side SAS card.
2-1 Turn off the server whose SAS card is to be replaced.
2-2 Replace the SAS card.
For details of the replacement procedure, refer to the user guide attached with the SAS
card.
3 Adjust the settings as necessary, using the ETERNUS DX60/DX80's GUI or CLI.
3-1 Delete the SAS address or host affinity setting assigned to the removed SAS card.
3-2 Referring to the information recorded in Step 1, register the SAS address or host
affinity of the new SAS card in the ETERNUS DX60/DX80.
4 When the setting is complete, confirm that the server can access the ETERNUS
DX60/DX80.
End of procedure
Refer
User guide for SAS card
"ETERNUS DX Disk storage systems Server Connection Guide (SAS)"
"ETERNUS DX60/DX80/DX90 Web GUI User Guide"
"ETERNUS DX60/DX80/DX90 CLI User Guide"