User guide
Chapter 7 Setup
> 7.4 Monitoring Setup
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
176
Copyright 2010 FUJITSU LIMITED
P3AM-3042-06ENZ0
3-2 Select the checkbox of "The ServerView control code is added to the comment line of
the MIB definition file" in "Option", and click the [Download] button.
Figure 7.39 [Download MIB File] screen
A confirmation screen appears.
3-3 Click the [OK] button.
The MIB definition file for SeverView monitoring is downloaded. A screen to save the
downloaded MIB definition file appears.
3-4 Save the downloaded file.
4 Set ServerView.
Install and set ServerView on the Industry standard server side.
Refer to "ServerView User's Guide" that is provided with the Industry standard server to
install and set ServerView.
5 Confirm notification for when an event occurs.
After setting up the ETERNUS DX60/DX80/DX90 and Industry standard server, sending
trap from the ETERNUS DX60/DX80/DX90 (SNMP Agent) to the Industry standard server
(SNMP Manager) can be confirmed by performing SNMP Trap Test.
5-1 Start GUI.
5-2 Click [Perform SNMP Trap Test] under the [Network Settings] menu on the [Global
Settings] tab in the GUI screen.
The [Perform SNMP Trap Test] screen appears.
I
MPORTAN
T
When registering the MIB information of an optional device, make
sure to specify "FJDARY-E60.MIB" that was exported in Step 3
Download the MIB definition file for SeverView monitoring.