User guide

Chapter 6 Cable Connection
> 6.7 Power Cord Connection
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
132
Copyright 2010 FUJITSU LIMITED
P3AM-3042-06ENZ0
The following table and figure show the connection path of an AC outlet cable and
connection figure respectively
Table 6.2 Connection path of a power cord (AC output cable) (AC outlet box (2U))
Connection source
(AC outlet box outlet)
Connection distribution
(power supply unit inlet)
AC outlet box A
OUT1 Controller enclosure PSU#0 inlet
OUT2 Drive enclosure 1 PSU#0 inlet
OUT3 Drive enclosure 2 PSU#0 inlet
OUT4 Drive enclosure 3 PSU#0 inlet
OUT5 Drive enclosure 4 PSU#0 inlet
OUT6 Drive enclosure 5 PSU#0 inlet
AC outlet box B
OUT1 Controller enclosure PSU#1 inlet
OUT2 Drive enclosure 1 PSU#1 inlet
OUT3 Drive enclosure 2 PSU#1 inlet
OUT4 Drive enclosure 3 PSU#1 inlet
OUT5 Drive enclosure 4 PSU#1 inlet
OUT6 Drive enclosure 5 PSU#1 inlet
AC outlet box C
OUT1 Drive enclosure 6 PSU#0 inlet
OUT2 Drive enclosure 7 PSU#0 inlet
OUT3 Drive enclosure 8 PSU#0 inlet
OUT4 Drive enclosure 9 PSU#0 inlet
AC outlet box D
OUT1 Drive enclosure 6 PSU#1 inlet
OUT2 Drive enclosure 7 PSU#1 inlet
OUT3 Drive enclosure 8 PSU#1 inlet
OUT4 Drive enclosure 9 PSU#1 inlet