User guide

Chapter 6 Cable Connection
> 6.7 Power Cord Connection
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
127
Copyright 2010 FUJITSU LIMITED
P3AM-3042-06ENZ0
The following table and figure show the connection path of an AC outlet cable and
connection figure respectively
Table 6.1 Connection path of a power cord (AC output cable) (AC outlet box (1U))
Connection source
(AC outlet box outlet)
Connection distribution
(power supply unit inlet)
The first ACS
OUTPUT #0 - 1 Controller enclosure PSU#0 inlet
OUTPUT #0 - 2 Drive enclosure 1 PSU#0 inlet
OUTPUT #1 - 1 Controller enclosure PSU#1 inlet
OUTPUT #1 - 2 Drive enclosure 1 PSU#1 inlet
The second
ACS
OUTPUT #0 - 1 Drive enclosure 2 PSU#0 inlet
OUTPUT #0 - 2 Drive enclosure 3 PSU#0 inlet
OUTPUT #1 - 1 Drive enclosure 2 PSU#1 inlet
OUTPUT #1 - 2 Drive enclosure 3 PSU#1 inlet
The third ACS
OUTPUT #0 - 1 Drive enclosure 4 PSU#0 inlet
OUTPUT #0 - 2 Drive enclosure 5 PSU#0 inlet
OUTPUT #1 - 1 Drive enclosure 4 PSU#1 inlet
OUTPUT #1 - 2 Drive enclosure 5 PSU#1 inlet
The fourth ACS
OUTPUT #0 - 1 Drive enclosure 6 PSU#0 inlet
OUTPUT #0 - 2 Drive enclosure 7 PSU#0 inlet
OUTPUT #1 - 1 Drive enclosure 6 PSU#1 inlet
OUTPUT #1 - 2 Drive enclosure 7 PSU#1 inlet
The fifth ACS
OUTPUT #0 - 1 Drive enclosure 8 PSU#0 inlet
OUTPUT #0 - 2 Drive enclosure 9 PSU#0 inlet
OUTPUT #1 - 1 Drive enclosure 8 PSU#1 inlet
OUTPUT #1 - 2 Drive enclosure 9 PSU#1 inlet