Technical data
A26361-K1000-Z221-1-7619, edition 2 55
Technical data
Electrical data
Regulations complied with: IEC 60950-1, EN 60950-1, UL 60950
CSA 22.2 No.60950-1
Protection class: I
Rated voltage range: 100 V – 240 V
Frequency: 50 Hz – 60 Hz
Maximum rated current
or:
100 V – 240 V /
5.0 A – 2.5 A
Maximum rated current (casing with monitor
socket)
100 V – 240 V /
6.0 A – 3.0 A
Maximum rated current (monitor socket
(output)):
100 V – 240 V /
3.0 A – 1.5 A
Dimensions
Width/depth/height: 203 mm/429 mm/446 mm
Weight
In basic configuration: approx. 11 kg
Environmental conditions
Environment class (3K2)
Environment class (2K2)
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature
Operating (3K2) 15 °C .... 35 °C
Transport (2K2) –25 °C .... 60 °C
Condensation must be avoided during operation.
Clearance required to ensure adequate ventilation:
Without air vents
With air vents
min. 10 mm
min. 200 mm
i
The data sheets of these devices contains further technical data. You will find the data
sheets on the internet at http://ts.fujitsu.com/support.