Mist or steam is emitted from the unit.
□ <In the Cooling or Dry mode> A thin mist may be generated by
condensation formed with sudden cooling process.
□ <In the Heating mode> Is the Automatic defrosting operation
working? In this case, steam may rise from the outdoor unit.
(Refer to page 5.)
Outdoor unit emits water.
□ <In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to page 5.)
Operation is delayed after restart.
□ Has the power supply turned from o to on suddenly?
In this case, the compressor will not operate for about 3 minutes
to prevent a blowout of the fuse.
□ Has the electrical breaker is turned o then on again?
In this case, the protection circuit will operate for about 3 minutes.
Immediately stop operation and turn o the electrical breaker in
following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or
diagnostics.
• Error sign is shown on the wired remote controller display or the
indicator lamps on the indoor unit.
NOTE:
For any troubleshooting related to the wireless LAN control, refer to the
setting manual for the WLAN adapter or the mobile app installed in your
smartphone or tablet PC.
■
State of indicator lamps
: The instruction is relating to the wireless LAN control
(optional).
Lighting pattern:
O, On, Blinking, Any state
State Causes and solutions
See
page
Automatic defrosting operation
⇒
Please wait until nishing the defrosting
(maximum of 15 minutes).
5
Filter indicator
⇒
Clean the air lter and reset the lter
sign.
5
Error code display
⇒
Consult authorized service personnel.
-
Timer setting error because of Auto restart
⇒
Reset the clock and timer settings.
5
Test run operation (for authorized
personnel only)
⇒
Press
to quit the test run.
-
The indoor unit is preparing the
rmware update.
You cannot operate the air conditioner.
Wait until the update is complete (for
a maximum of 30 minutes).
6
or
<While the operation is stopped>
The indoor unit is in the rmware
update.
You cannot operate the air conditioner.
Wait until the update is complete (for
a maximum of 30 minutes).
6
(3 times)
(Fast)
State Causes and solutions
See
page
(Slow)
<While the operation is stopped>
The rmware update of the indoor
unit is complete. The settings from
the wireless remote controller are
initialized.
Control the air conditioner from the
wireless remote controller to resend
the settings.
6
<While the operation is stopped>
If you cannot operate the air
conditioner, the malfunction may occur
on the rmware of the indoor unit.
Consult authorized service personnel.
-
Restricted function
6
(Slow)
(Slow)
(In multi-split connection) Standby mode
⇒
Check the set operation mode of the
indoor units.
6
■
Manual Auto operation and Filter indicator
reset
You can operate the air conditioner with
on the indoor
unit.
Status Length of pressing down Mode or operation
In operation More than 3 seconds Stop
Stopping 2 seconds or less Filter indicator reset
More than 3 seconds and
less than 10 seconds
Auto *
1)
More than 10 seconds
(Only for servicing.*
2)
)
Forced cooling
In Heating
operation
2 seconds or less (Special
setting)
*3)
Emergency heat
*1) In multi-split connection, the operation mode follows the other indoor
units.
*2) To stop the forced cooling, press this button or
on the wireless
remote controller.
*3) Refer to “Emergency heat (page 6)” for details.