Instruction Manual
En-2
CAUTION
• Do not direct the airow at replaces or heating apparatus.
• Do not block or cover the outlet port and air intake grille.
• Do not apply any heavy pressure to radiator ns.
• Do not climb on, place objects on, or hang objects
from this product.
• Do not place any other electrical products or
household belongings under this product. Dripping
condensation from this product might get them wet,
and may cause damage or malfunction of your
property.
• Do not expose this product directly to water.
• Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects.
This may cause quality deterioration of those items.
• Do not expose animals or plants to the direct airow.
• Do not drink the drainage from the air conditioner.
• Do not touch the aluminum ns of heat exchanger
built-in this product to avoid personal injury when you
maintain the unit.
• Do not stand on unstable steps when operating or
cleaning this product. It may overturn and can cause
injury.
This product contains uorinated greenhouse gases.
2. NAME OF PARTS
The remote controller is optional. You can select from the
following types of remote control.
- Wireless remote controller
- Wired remote controller
- Wireless LAN control
To check the available model of remote control, consult authorized
service personnel.
For detailed instructions on how to operate, refer to the
operation manual of the remote controller.
Horizontal louvers
Indicator lamps
*1)
Remote control signal receiver
For Manual Auto operation and
Filter indicator reset (Refer to page 8.)
Air intake grille
Air lter (in the air intake grille)
*1) Indicator lamps light in the following conditions.
Name
Color Operation or condition
Operation Green Normal operation
Timer Orange Timer operation
*2)
Economy Green Economy operation
Minimum heat operation
*2)
*2) The lamp lights only when the operation is set from the
wireless remote controller.
3. BASIC OPERATIONS
NOTES: For detailed instructions on how to operate, refer to the
operation manual of the remote controller.
The operation mode and the temperature setting range are
shown in the following table.
Operation mode Temperature setting range
Auto/Cooling/Dry 64 - 88 °F (18.0 - 30.0 °C)
Heating 60 - 88 °F (16.0 - 30.0 °C)
■
Auto mode
The air conditioner selects the appropriate operation mode
(Cooling or Heating) according to your room’s present
temperature.
Room temperature Operation
Higher than the setting temperature Cooling
Close to the setting temperature Determined by outdoor
temperature
Lower than the setting temperature Heating
Dened temper-
ature in tempera-
ture setting
Determined by
outdoor temperature
Cooling mode
Heating mode
When Auto mode is rst selected, the fan will operate at low speed for
about a few minutes, during which time the indoor unit detects the room
conditions and selects the operation mode.
When the air conditioner has adjusted your room’s temperature to near
the thermostat setting, it will begin monitor operation.
In the monitor operation mode, the fan will operate at low speed. If the
room temperature subsequently changes, the air conditioner will once
again select the appropriate operation (Heating, Cooling) to adjust the
temperature to the value set in the thermostat.
If the mode automatically selected by the unit is not what you wish,
select one of the mode operation (Heating, Cooling, Dry, Fan).
■
Cooling mode
Use to cool your room.
NOTES: Set the temperature lower than the current room temperature.