SPECIFICATIONS
MODEL
INDOOR UNIT ASGA18FMTB ASGA24FMTB
OUTDOOR UNIT AOGA18FMTBH AOGA24FMTBH
TYPE COOLING MODEL
POWER 220-240V ~ 50Hz
COOLING
CAPACITY [kW] 5.40 - 5.40 7.15 - 7.15
POWER INPUT [kW] 1.79 - 1.87 2.44 - 2.60
CURRENT [A] 8.2 - 8.2 11.8 - 12.6
ENERGY EFFICIENCY RATIO [kW/kW] 3.02 - 2.89 2.93 - 2.75
MAX. PRESSURE
SUCTION [MPa] 1.20
DISCHARGE [MPa] 4.20
REFRIGERANT (R410A) [kg] 1.10 1.55
DIMENSIONS & WEIGHT (NET)
INDOOR UNIT
HEIGHT [mm] 320
WIDTH [mm] 998
DEPTH [mm] 238
WEIGHT [kg] 13
OUTDOOR UNIT
HEIGHT [mm] 650
WIDTH [mm] 830
DEPTH [mm] 320
WEIGHT [kg] 47 55
TEMPERATURE AND HUMIDITY RANGE
OUTDOOR TEMPERATURE
COOLING/DRY [°C] 21 to 52
INDOOR TEMPERATURE
COOLING/DRY [°C] 18 to 32
INDOOR HUMIDITY [%] 80 or less
● Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor
unit. According to IEC 704-1 and ISO 3744.
● If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower
temperatures than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
● Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary
dwellings.
● If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor
unit, and drip onto the fl oor or other objects underneath.
9385989320-02_OM_EN.indd 179385989320-02_OM_EN.indd 17 19-Jul-19 15:04:3919-Jul-19 15:04:39