FLOOR TYPE
AGU9-15RLF
FLOOR TYPE
AGU9-15RLF
FEATURES1.
MODEL
AGU9RLF / AOU9RLFFH
AGU12RLF / AOU12RLFFH
AGU15RLF / AOU15RLFFH
FEATURES
Energy efciency
z
Extra Cold Climate Area Model
AGU9RLF AGU12RLF AGU15RLF
Seasonal Energy Efciency Ratio (SEER) 26.0 22.7 20.3
Heating Seasonal Performance Factor (HSPF) 12.4 11.3 11.0
MEASUREMENT CONDITIONS
ANSI/ASHRAE STANDARD 37-1988
2-Fan & Wide airow
Low outdoor air temperature correspondence
z
Corresponds to heating operation at -15°F (-26°C) outdoor air temperature (AOU9, 12, 15RLFFH)
Heating
-15 to 75°F
(-26 to 24°C)
Cooling
at operation
start
Prevents cold air
from falling
at stable
operation
at operation
start
Heating
Window
Prevents cold
draft from
window
at stable
operation
Specication improvement to allow operation
under extremely low outdoor temperature -15°F
(-26°C) without trouble
Extra cold climate area model
Freezing
prevention of base
Structural
improvements
Improvement of cold-
proof specications of
parts
Freezing prevention
150W Heater
Base
Many drain holes