Design and Technical Manual

- (02 - 02) -
OUTDOOR UNIT
AOU9-15RLFFH
OUTDOOR UNIT
AOU9-15RLFFH
DIMENSIONS2.
MODEL
: AOU9RLFFH, AOU12RLFFH, AOU15RLFFH
Unit: in. (mm)
INSTALLATION PLACE
4-5/16
(110)
8-1/4 (209)
6-7/8 (175)
12-5/8 (320)
4-ø7/16 (11.3) hole
21-1/4 (540)
Airflow
ø13/16 (20) hole
Bottom view
Top view
Front view Side view
2-3/16
(55)
hole
1 (25)
3/8 (10) 3/8 (10)
hole
4 (102)
3/8 (10)
1 (25)
3/8 (9)
13/16 (20)
24-7/16 (620)
31-1/8 (790)13/16 (20) 2-9/16 (65) 11/16 (18) 11-7/16 (290)
13-7/8 (352)
7/8 (23)
24 (600) or more
4 (100) or more
8 (200) or more
4 (100)
or more
10 (250) or more
(Service space)
CAUTION
In areas with heavy snowfall, if the intake and outlet of the
outdoor unit is blocked with snow, it may be difficult to
warm up and likely to cause breakdown. In such condition,
be sure to construct a canopy or baffle board stand.
If the space is larger than is stated, the condition will be the same as those without any no obstacles.