(Unit : in. (mm))
Capacity
SEER
EER
HSPF
Running Current
Noise Level (Indoor)
Noise Level (Outdoor)
Airflow Rate (High)
Piping Connections (Liquid / Gas)
Max Pipe Length / Pre-Charge Length
Max Height Difference
Refrigerant
Net Dimension
H x W x D
Operation Range
(Outdoor)
Cooling / HeatingInput Power
Power Source
Cooling
Heating
Cooling
Cooling
Heating
Cooling/Heating
Cooling
Indoor/Outdoor
Cooling
Heating
Cooling
High/Quiet
Indoor
Outdoor
ft. (m)
˚FC)DB
W
Btu/W
Btu/W
Btu/W
A
CFM (m³/h)
in. (mm)
lbs (kg)
in. (mm)
lbs (kg)
in. (mm)
dB(A)
V / Ø / Hz
Btu
Model No.
Indoor unit
Outdoor unit
AGU9RLF
AOU9RLFF
9000
12000
600 / 880
24.00
15.00
12.60
40 / 23
49
335(569)/1206(2049)
AGU15RLF
AOU15RLFF
14200
18000
1130 / 1580
20.30
12.50
11.20
44 / 23
54
383(651)/1457(2475)
Ø6.35/Ø12.7
208/230V, , 60Hz
23-5/8(600) / 29-1/8(740) / 7-7/8(200)
31 (14)
24-7/16(620) / 31-1/8(790) / 11-7/16(290)
66(20) / 49(15)
49(15)
14(-10) to 115(46)
R410A
84 (38)
Ø6.35/Ø9.53
AGU9RLF
AOU9RLFFH
9000
12000
600 / 880
26.00
15.00
40 / 23
49
335(569)/1206(2049)
86 (39)
AGU15RLF
AOU15RLFFH
14
200
18000
1130 / 1580
20.30
12.50
44 / 23
54
383(651)/1457(2475)
88 (40)
Ø6.35/Ø12.7
AGU12RLF
AOU12RLFF
12000
16000
910 / 1440
22.70
13.10
11.60
40 / 23
53
335(569)/1457(2475)
-5(-21) to 75(24)
Extra Cold Climate Area Model
AGU12RLF
AOU12RLFFH
12000
16000
910 / 1440
22.70
13.10
40 / 23
53
335(569)/1457(2475)
-15(-26) to 75(24)
Ø6.35/Ø9.52
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
http://www.fujitsu-general.com/
Copyrigh 2013 Fujitsu General Limited. All rights reserved. 3UFNP1-1309E
•Specifications and design are subject to change without notice for further improvement.
Distributed by :
•Actual products’ colors may be different from the colors shown in this printed material.
Note: Specifications are based on the following conditions.
Cooling : Indoor temperature of 80°F (26.67°C) DB / 67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB / 75°F (23.9°C) WB.
Heating : Indoor temperature of 70°F (21.11°C) DB / 59°F (15°C) WB, and outdoor temperature of 47°F (8.33°C) DB / 43°F (6.11°C) WB.
Pipe length : 24ft. 7in. (7.5m)
Height difference : 0ft (0m) (Outdoor unit - Indoor unit)
Indoor unit : AGU9RLF / AGU12RLF / AGU15RLF Outdoor unit : AOU9RLFF / AOU12RLFF / AOU15RLFF
AOU9RLFFH / AOU12RLFFH / AOU15RLFFH
Sleep timer : The micro-computer gradually changes
the room temperature automatically to allow a
comfortable night's sleep.
V-PAM control models
Economy mode : Limits the maximum operation
current, and performs operation with the power
consumption suppressed.
Program timer : This digital timer allows selection of
one of four options :
ON, OFF, ONOFF or OFF → ON.
Long-life ion deodorization filter : The filter
deodorizes by powerfully decomposing absorbed odors
using the oxidizing and reducing effects of ions
generated by the ultra-fine-particle ceramic.
Apple-catechin filter : Fine dust, invisible mold spores,
and harmful microorganisms are absorbed into the filter by static
electricity, and further growth is inhibited and deactivated by the
polyphenol extracted from apples.
Auto restart : In the event of a temporary power failure, the
air conditioner will automatically restart in the same
operating mode as before, once the power supply is restored.
Up / down swing flaps : The up/down flaps
automatically swing up and down.
Wired remote controller (High grade) : UTY- RVNUM
Wired remote controller : UTY- RNNUM
Simple remote controller : UTY- RSNUM
Half Concealed Kit : UTR-STA
External Connect Kit : UTY-XWZXZ5
Automatic airflow adjustment : The micro-computer
automatically adjusts the airflow effectively to follow
the changes of room temperature.
Washable panel
F
ujitsu
G
eneral
(S
hanghai
)
C
o., Ltd.
ISO
900
1
C
erti
f
ied number : 01 100 7926
9
ISO
14001
C
erti
f
ied number : 310102-UK
7-7/8 (200)
23-5/8 (600)
29-1/8 (740)
Front view Side view
13/16(20)
24-7/16 ( 620 )
13/16(20)
3/8(9)
31-1/8 ( 790 )
Front view Side view
2-9/16(65) 7/8(23)11-7/16(290)11/16(23)
13-7/8(352)
Auto-changeover : The unit automatically switches
between heating and cooling modes based on the
temperature setting and the room temperature.
Minimum Heat operation : The room temperature can be
set to go no lower than 50°F (1C), thus ensuring that the
room does not get too cold when not occupied.
Powerful mode : Operation at maximum airflow and
compressor speed, quickly making the room
comfortable.
POWERFULPOWERFUL
Filter sign : Indicates the filter cleaning period
by lamp.
Feature explanation
Optional parts
Dimensions
Specifications
(Unit : in. (mm))
Capacity
SEER
EER
HSPF
Running Current
Noise Level (Indoor)
Noise Level (Outdoor)
Airflow Rate (High)
Piping Connections (Liquid / Gas)
Max Pipe Length / Pre-Charge Length
Max Height Difference
Refrigerant
Net Dimension
H x W x D
Operation Range
(Outdoor)
Cooling / HeatingInput Power
Power Source
Cooling
Heating
Cooling
Cooling
Heating
Cooling/Heating
Cooling
Indoor/Outdoor
Cooling
Heating
Cooling
High/Quiet
Indoor
Outdoor
ft. (m)
˚FC)DB
W
Btu/W
Btu/W
Btu/W
A
CFM (m³/h)
in. (mm)
lbs (kg)
in. (mm)
lbs (kg)
in. (mm)
dB(A)
V / Ø / Hz
Btu
Model No.
Indoor unit
Outdoor unit
AGU9RLF
AOU9RLFF
9000
12000
600 / 880
24.00
15.00
12.60
40 / 23
49
335(569)/1206(2049)
AGU15RLF
AOU15RLFF
14200
18000
1130 / 1580
20.30
12.50
11.20
44 / 23
54
383(651)/1457(2475)
Ø6.35/Ø12.7
208/230V, , 60Hz
23-5/8(600) / 29-1/8(740) / 7-7/8(200)
31 (14)
24-7/16(620) / 31-1/8(790) / 11-7/16(290)
66(20) / 49(15)
49(15)
14(-10) to 115(46)
R410A
84 (38)
Ø6.35/Ø9.53
AGU9RLF
AOU9RLFFH
9000
12000
600 / 880
26.00
15.00
40 / 23
49
335(569)/1206(2049)
86 (39)
AGU15RLF
AOU15RLFFH
14
200
18000
1130 / 1580
20.30
12.50
44 / 23
54
383(651)/1457(2475)
88 (40)
Ø6.35/Ø12.7
AGU12RLF
AOU12RLFF
12000
16000
910 / 1440
22.70
13.10
11.60
40 / 23
53
335(569)/1457(2475)
-5(-21) to 75(24)
Extra Cold Climate Area Model
AGU12RLF
AOU12RLFFH
12000
16000
910 / 1440
22.70
13.10
40 / 23
53
335(569)/1457(2475)
-15(-26) to 75(24)
Ø6.35/Ø9.52
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
http://www.fujitsu-general.com/
Copyrigh 2013 Fujitsu General Limited. All rights reserved. 3UFNP1-1309E
•Specifications and design are subject to change without notice for further improvement.
Distributed by :
•Actual products’ colors may be different from the colors shown in this printed material.
Note: Specifications are based on the following conditions.
Cooling : Indoor temperature of 80°F (26.67°C) DB / 67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB / 75°F (23.9°C) WB.
Heating : Indoor temperature of 70°F (21.11°C) DB / 59°F (15°C) WB, and outdoor temperature of 47°F (8.33°C) DB / 43°F (6.11°C) WB.
Pipe length : 24ft. 7in. (7.5m)
Height difference : 0ft (0m) (Outdoor unit - Indoor unit)
Indoor unit : AGU9RLF / AGU12RLF / AGU15RLF Outdoor unit : AOU9RLFF / AOU12RLFF / AOU15RLFF
AOU9RLFFH / AOU12RLFFH / AOU15RLFFH
Sleep timer : The micro-computer gradually changes
the room temperature automatically to allow a
comfortable night's sleep.
V-PAM control models
Economy mode : Limits the maximum operation
current, and performs operation with the power
consumption suppressed.
Program timer : This digital timer allows selection of
one of four options :
ON, OFF, ONOFF or OFF → ON.
Long-life ion deodorization filter : The filter
deodorizes by powerfully decomposing absorbed odors
using the oxidizing and reducing effects of ions
generated by the ultra-fine-particle ceramic.
Apple-catechin filter : Fine dust, invisible mold spores,
and harmful microorganisms are absorbed into the filter by static
electricity, and further growth is inhibited and deactivated by the
polyphenol extracted from apples.
Auto restart : In the event of a temporary power failure, the
air conditioner will automatically restart in the same
operating mode as before, once the power supply is restored.
Up / down swing flaps : The up/down flaps
automatically swing up and down.
Wired remote controller (High grade) : UTY- RVNUM
Wired remote controller : UTY- RNNUM
Simple remote controller : UTY- RSNUM
Half Concealed Kit : UTR-STA
External Connect Kit : UTY-XWZXZ5
Automatic airflow adjustment : The micro-computer
automatically adjusts the airflow effectively to follow
the changes of room temperature.
Washable panel
F
ujitsu
G
eneral
(S
hanghai
)
C
o., Ltd.
ISO
900
1
erti
ied number : 01 100 7926
ISO
14001
C
erti
f
ied number : 310102-UK
7-7/8 (200)
23-5/8 (600)
29-1/8 (740)
Front view Side view
13/16(20)
24-7/16 ( 620 )
13/16(20)
3/8(9)
31-1/8 ( 790 )
Front view Side view
2-9/16(65) 7/8(23)11-7/16(290)11/16(23)
13-7/8(352)
Auto-changeover : The unit automatically switches
between heating and cooling modes based on the
temperature setting and the room temperature.
Minimum Heat operation : The room temperature can be
set to go no lower than 50°F (1C), thus ensuring that the
room does not get too cold when not occupied.
Powerful mode : Operation at maximum airflow and
compressor speed, quickly making the room
comfortable.
POWERFULPOWERFUL
Filter sign : Indicates the filter cleaning period
by lamp.
AGU9RLF, AGU12RLF, AGU15RLF
AOU9RLFFH, AOU12RLFFH, AOU15RLFFH
9RLFFH
HEAT PUMP
12RLFFH
HEAT PUMP
15RLFFH
HEAT PUMP
Nominal Cooling BTU/h 9,000 12,000 14,200
Min.~Max. Cooling
BTU/h
3,100~13,000 3,100~14,300 3,100~17,700
Nominal Heating BTU/h
12,000 16,000 18,000
Min.~Max. Heating BTU/h
3,100~18,800 3,100~19,500 3,100~20,800
HSPF BTU/hW 12.4 11.3
11.0
SEER BTU/hW 26.0 22.7 20.3
EER
Clg
16.0 13.1 12.5
Clg. Operating Range °F(°C)
14~115 (-10~46) 14~115 (-10~46) 14~115 (-10~46)
Htg. Operating Range °F(°C)
-15~75 (-26~24) -15~75 (-26~24) -15~75 (-26~24)
Moisture Removal Pt./h(l/h) 2.75 (1.3) 3.8 (1.8) 4.44 (2.1)
Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1
MAX.CRT.BKR
(A) 15 15 20
Air Circ.
C.F.M. (m
3
/h): Hi 335 (570) 335 (570) 383 (650)
Medium 271 (460) 271 (460) 306 (520)
Low 212 (360) 212 (360) 235 (400)
Quiet 159 (270) 159 (270) 159 (270)
Noise Level
dB(A)Clg/Htg: Hi 40/40 40/40 44/43
Medium 35/35 35/35 38/37
Low 29/29 29/29 31/29
Quiet 23/23 23/23 23/23
Outdoor Noise Level dB(A) Clg/Htg
50/50 52/52 54/54
Current
Rated (A): Cooling 2.9 4.2 5.1
Heating 4.1 6.7 7.0
Power Use
Rated (kw): Cooling .56 .97 1.13
Heating .88 1.44 1.58
Fan Speeds Stage 4+Auto 4+Auto 4+Auto
Air Direction: Horizontal Manual Manual Manual
Vertical Auto Auto Auto
Air Filter Washable Washable Washable
Apple Catechin Filter Yes Yes Yes
Ion Deoderizing Filter Yes Yes Yes
Connection Method Flare Flare Flare
Combined Min. Lgth
Ft (m) 10 (3) 10 (3) 10 (3)
Combined Max. Lgth
Ft (m)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
Max. Vertical Diff. Ft (m) 49 (15) 49 (15) 49 (15)
Conn. Pipe Diameter
Inch
Suc. 3/8 Dis. 1/4 Suc. 3/8 Dis. 1/4 Suc. 1/2 Dis. 1/4
Net Weight lbs. (kg)
31 (14) 86 (39) 31 (14) 86 (39) 31 (14) 88 (40)
Dimensions: Height Inch
23-5/8 24-7/16 23-5/8 24-7/16 23-5/8 24-7/16
mm 600 620 600 620 600 620
Width Inch
29-1/8 31-1/8 29-1/8 31-1/8 29-1/8 31-1/8
mm 740 790 740 790 740 790
Depth Inch
7-7/8 11-7/16 7-7/8 11-7/16 7-7/8 11-7/16
mm 200 290 200 290 200 290
Refrigerant
R410A R410A
R410A
Indoor
AGU9RLF
Outdoor
AOU9RLFFH
Indoor
AGU12RLF
Outdoor
AOU12RLFFH
Indoor
AGU15RLF
Outdoor
AOU15RLFFH
Note: Figures are based on 230 Volts.
STANDARD FEATURES
Wireless
Wireless Remote Control
Apple Catechin Filter
Ion
Ion Deoderizing Filter
Sleep
Sleep Timer
24 Hour
24 Hour Timer
Up/Down
Auto Louver: Up/Down
Adjust
Auto Mode
50˚F
Heat
Minimum Heat Mode
Economy
Economy Mode
Restart
Auto Restart/Reset
Changeover
Auto
Auto Changeover
Powerful
Powerful Mode
ACCESSORIES
Wired Remote Controller: UTY-RVNUM
Backlit and includes room temperature
Wired Remote Controller: UTY-RNNUM
Simple Remote Controller: UTY-RSNUM
Dry Contact Wire Kit: UTY-XWZXZ5
DIMENSIONS
Designer wireless
remote control