User Manual

A26361-K622-Z100-1-7619 41
Technical data
Electrical data
Regulations complied with: EN 60950 / VDE 0805
Protection class: I
Rated voltage range: (selectable) 100 V to 125 V / 200 V to 240 V
Frequency: 50 Hz - 60 Hz
Max. rated current
System unit 100 V -120 V/5.0 A
200 V -240 V/3.0 A
Maximum power draw in operation: < 50 W *)
Minimum power draw in operation:
reduced by Windows 9x
Power management advanced
<30W *)
Power draw in energy saving mode: < 30 W *)
Power draw in the 'ready' status < 5 W *)
Noise emission: Sound power level (L
WAd
) < 55 dB (A) *)
*) These values only apply for a SCENIC eD with the configuration below. When additional or
other components are incorporated, the power consumption or the sound emission (L
WAd
)in
energy saving mode may exceed the requirements for the environment symbol ("Blue Angel")
(30 W or 55 dB).
Processor (256 Kbyte cache): Pentium III Processor at 800 MHz
Main memory: 128 Mbyte
Floppy disk drive: 1.44 Mbyte
Hard disk drive: 10 Gbyte
Software: Windows 98 Power management - Advanced...
CD-ROM drive: 48fold
LAN: 10/100 Mbit Ethernet Controller
Dimensions
Width/depth/height: 380 mm/440 mm/ 130 mm
Weight
in basic configuration approx. 8.5 kg
Environmental conditions
Environment class 3K2
Environment class 2K2
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature:
Operating (3K2)
Transport (2K2)
15 °C .... 35 °C
-25 °C .... 60 °C
Condensation in operating must be avoided.
Clearance required to ensure adequate ventilation:
left-hand side
front
rear
min. 200 mm
min. 200 mm
min. 200 mm