Attach one end of the CAT 5 cabling that will run between your KVM s2-Adapt-
er and unit to the RJ45 connector on the KVM s2-Adapter.
Connect the other end of the CAT 5 cable to the desired Rack Interface (RI)
port on the back of your KVM s2-1611 unit.
Repeat steps 2-4 for all servers you wish to attach.
When connecting a Sun KVM s2-Adapter, you must use a multi-sync monitor
to accommodate Sun computers that support both VGA and sync-on-green
or composite sync.
3.3.5 Adding a KVM switch
You can add your cascade switches to the KVM s2-1611 system for better inte-
gration into your existing conguration. In a cascaded system, each RI port will
accommodate up to 24 servers.
Figure 4: KVM s2-1611 Conguration with a Cascaded KVM Switch
Connecting an Adapter to each server
1 3 5 7 9 11 13 15
2 4 6 8 10 12 14 16
KVM s2-1611
Appliance
KVM s2-Adapter
PS/2, USB and Sun cables
are available
Tiered KVM s2 Appliance
Cascade to a KVM s2-1611, 1602
or 0801 via a CAT 5 cable con-
nected from an RI port to the ACI
port on the KVM s2-1602
Cascaded
KVM Switch
Local Analog
User
Server 1
Server 1
12 590-332-501E
KVM s2-1602 Appliance
KVM s2-Adapter