System configurator and order-information guide Hub Switch RX600 S3

System configurator and order-information guide
E
PRIMERGY RX600 S3 Status 2007-01-24
Section
V
USB devices / optical devices
One of the following
USB
devices
must be used
for integrating the drivers during installation
process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done:
1) USB DVD+-RW:
S26391-F3152-L300
Traveller III DVD DL super multi drive
(USB cable included)
2) FDD USB (external):
S26391-F264-L226
external USB FDD
(USB cable included)
3) USB Keyboard:
S26381-K340-V120
KBPC PX D, professional keyboard
4) USB Mouse:
S26381-K403-L100
Optical Wheel Mouse
5) USB Memorybird: S26391-F6046-L24
Memorybird 1GB
Additionally a monitor can be connected to the VGA 15-pin interface.
S26361-F3123-E1 S26361-F3236-E1
CD-RW / DVD drive 0.5" DVD-RW 8x super multi drive
24/24/24x / 8x ATAPI all formats, DUAL/DL, DVD-RAM
1x
CD-RW only with W2K, W3K, Linux only W2K, W3K and Linux
0.5 x 5.25", anthracite bezel 0.5 x 5.25", anthracite bezel
max. 1x per system max. 1x per system
Section
VI
Hard disk drives
HDD´s for SCSI Base Units
S26361-F3121-E173 S26361-F3121-E114 S26361-F3121-E130
Hard disk 73GB Hard disk 146GB Hard disk 300GB
10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins)
hot plug/hot replace tray hot plug/hot replace tray hot plug/hot replace tray
occupies 1" bay occupies 1" bay occupies 1" bay
SCSI/RAID controller necessary SCSI/RAID controller necessary SCSI/RAID controller necessary
max. 5x per system max. 5x per system max. 5x per system
max. 5
S26361-F3121-E536 S26361-F3121-E573 S26361-F3121-E514
Hard disk 36GB Hard disk 73GB Hard disk 146GB
15.000rpm,<4ms, 8MB Cache 15.000rpm,<4ms, 8MB Cache 15.000rpm,<4ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins)
hot plug/hot replace tray hot plug/hot replace tray hot plug/hot replace tray
occupies 1" bay occupies 1" bay occupies 1" bay
SCSI/ RAID controller necessary SCSI/ RAID controller necessary SCSI/ RAID controller necessary
max. 5x per system max. 5x per system max. 5x per system
HDD´s for SAS Base Units
S26361-F3208-E136 S26361-F3208-E173
HD 36GB 10krpm 2.5" HD 73GB 10krpm 2.5"
max. 8
10000rpm,<4,5ms, 8MB Cache 10000rpm,<4,5ms, 8MB Cache
SAS 3Gb/s SAS 3Gb/s
hot plug/hot replace tray hot plug/hot replace tray
max. 8x per base unit max. 8x per base unit
F
Fujitsu Siemens Computers Enterprise Products PRIMERGY Server 11 of 17