- Fujitsu Siemens Server User's Guide

U25339-J-Z126-1-7600 95
Troubleshooting Problems with the S130
Ê Once the message SHUTDOWN COMPLETED is displayed, switch the S130 to CE mode by
switching the CE key on the inside of the maintenance panel of the S130 to the position
“Maintenance Mode On”.
The CE mode is indicated by the display CE on the control panel of the S130 (see
page 12f) and in line 23 of the SVPST0 window on the SKP operating terminal (see
page 40).
Ê Select the SVPST0 window on the SKP operating terminal (see page 36).
Ê Press the key. It switches to CE mode in the Index Frame.
Ê Select the Generation Frame by entering the frame code GE and press the key.
Ê Enter 1 in the input field SETUP ITEM => to select the SYSTEM FEATURE and press the
key.
The following frame is displayed:
Figure 45: GENERATION FRAME: SYSTEM screen
Ê Enter Y in the field UPDATE => to modify the generation. Confirm your input by pressing
the key.
Ê Enter N for the defective CPU and Y for the next available CPU. Confirm your input by
pressing the key.
Ê Press the key.
Ê Respond to the question DO YOU WANT TO SAVE SETUP DATA: ? in the subsequent frame
with Y. Confirm your input by pressing the key.
P2
ENTER
ENTER
----- GENERATION FRAME: SYSTEM ----- E02L01F-01Q+013
--- SYSTEM FEATURE ---
MODEL => GS8600 FVC => 60 FMODEL => 8600
TYPE => /40 IVC => 00 IMODEL => 3090
--- INSTALLATION (Y/N) ---
CPU0 => Y CPU1 => Y CPU2 => N CPU3 => N
CPU4 => N CPU5 => N CPU6 => N CPU7 => N
MSU0 => Y MSU1 => Y
CHP0 => Y CHP1 => N CHP2 => Y CHP3 => N
IOPA0=> Y IOPA1=> Y IOPA2=> N IOPA3=> N
IOPA4=> Y IOPA5=> N IOPA6=> N IOPA7=> N
--- MULTI CLUSTER FEATURE ---
DOMAIN SSU CAPACITY => 00000000 (MB)
GSIGP I/O RESET TIME-OUT => 30 (SEC)
UPDATE => N (Y/N) PF3:RETURN PF6:CANCEL PF7:PAGE UP PF8:PAGE DOWN
CL-0 CPU-0 CHP-0 RUN
M CE TEST
LTG TAST
ENTER
ENTER
P3
ENTER