The synchronization accuracy of SyncE is maintained for 24 hrs under the following condition.
■ SyncE clock at GM C synchronizes with 1pps of PTP.
■ SyncE clock of RU is synchronized with the GM C before loss of PTP.
The RU shall support IEEE 1914.1, ITU-T G.826x, G.827x series specified in ORAN-WG4.CUS.0-v02.00.
Counter
The RU supports the counters of "object-unit RU" on KPI counter specified in ORAN-WG4.CUS.0-v02.00.
Optical Module
The following table lists the recommended SFP parts that can be installed in the RU.
SFP Type (Transmission
distance)
Vendor Part Number
10 km Molex TPP4XGFLRIFUJE2x
II-VI Incorporated FTLX1472M 3BTL-FW
Accelink Technologies Co., Ltd RTXM 228-409-C74
40 km Sumitomo Electric Industries, Ltd. SPP5200SV-FG-W
Accelink Technologies Co., Ltd. RTXM 228-424-C74
APAC Opto Electronics Inc. LE48-H3L-TI-N-LF
3.10.2
Radio Performance
The RU meets the radio specifications described in this section under all environmental conditions specified,
unless otherwise noted.
RU Hardware Feature
Performance Requirement
46
Release 1.0 · Issue 1, March 2021
Fujitsu and Fujitsu Customer Use Only