User's Guide

Table Of Contents
Immunity Specification
Test standard 3GPP 38.113
Table 4
Specification In 3GPP 38.113
Phenomenon Application Reference Standard
Detail
Specification
Criteria
RF electromagnetic field (80
6000 M Hz)
Enclosure IEC 61000-4-3 Radiated Immunity A
Electrostatic discharge Enclosure IEC 61000-4-2 Electric Discharge B
Fast transients common mode Signal, telecommunications and
control ports,
DC power input ports
IEC 61000-4-4 Fast Transients
Common Mode
B
RF common mode 0, 15…80 M Hz Signal, telecommunications and
control ports,
DC power input ports
IEC 61000-4-6 RF Common Mode A
Surges, common and differential
mode
AC power input ports,
telecommunications port
IEC 61000-4-5 Resistibility of
Lightning
B
Radiated Immunity
Test Standard 3GPP 38.113
IEC 61000-4-3 Level 3
Test mode Traffic mode, no test in RX exclusion band
80 – 6000 M Hz 3 V/ m, AM 80%
Performance Criteria A
Electric Discharge
Test standard 3GPP 38.113
IEC 61000-4-2
Contact discharge ±4 kV
Air discharge ±8 kV
Performance Criteria B
RU Hardware Feature
Environment Specifications
27
Release 1.0 · Issue 1, March 2021