User's Guide

Table Of Contents
3.3.4
Product Safety Specifications
Basic Specification UL62368-1 2nd edition
Outdoor Specification UL 50E (UL60950-22) CSA-C22.2
Product Safety
Approvals/
Certification
Electrical equipment is required to be approved by a Nationally Recognized Testing Laboratory
(NRTL). A test report issued by a NRTL shows compliance with UL 50E Ed.1 2007/ CAN/ CSA-C22.2
NO. 94.2-07 and required encapsulation class.
3.3.5
EMC
Conducted Emission
Pow er Port Unintentional radiation: CFR 47, Part 15B
Test mode: traffic mode
RET Port Conducted emissions 3GPP 38.113
Test mode: traffic mode
Radiated Emission
Unintentional
Radiation
CFR 47, Part 15B
Test mode: traffic mode
Test standard 3GPP 38.113
Radio frequency
radiation exposure
limits
CFR 47, Part 1.1310
Immunity
Immunity Performance
Test standard 3GPP 38.113
Performance Criteria A The EUT must continue to operate as intended during and after test.
No degradation of performance or loss of functions.
Performance Criteria B Temporary loss of function is allowed, provided the function is self-recoverable.
Radio must meet performance criteria before and after completion of test.
RU Hardware Feature
Environment Specifications
26
Release 1.0 ยท Issue 1, March 2021
Fujitsu and Fujitsu Customer Use Only