Chemically Active Substance
Gas Exposure IEC-60068-2-60
Test method JIS-C-0048 M ethod-4
Criteria Test piece is used. Rating 4 in JIS H8502.
Salt fog Telcordia GR-487
3.3.2
Transport and Storage Requirements
Packaged Equipment
Shock Drop
Telcordia GR 63
M ass < 40 kg Height 500 mm
M ass < 50 kg Height 400 mm
Criteria M ust not sustain any physical damage or deterioration in functional performance
Compliant with GR-63 standards
Storage Temperature –33…+40 °C (91.4…104 °F)
Relative Humidity 15…100%
Absolute Humidity 0.26…25 g/ m3
Change of
Temperature
0.5 °C/ min (32.9 °F/ min)
Vibration ETSI EN 300 019-2-4, Severity class 1
Earthquake Telcordia GR-63, Zone 4
3.3.3
Mechanical Specifications
Volume 30 L
Dimension (W x H x D) 400 x 380 x 200 mm
Antenna Connector
Type
4.3-10 RF Connector
Antenna Control
Interface
AISG
Pow er Supply –58…–36 V DC
M aximum Pow er
Consumption
1300 W
W eight 29 kg; 63.9341 lb (without mounting brackets)