Table 2 (Cont.)
M easurement Function
Item Specification
Alarm/ control The RU reports an alarm when the following status changes occur on the RU.
Note: In case of the RU HW failure, the RU provides alarm to the EM S.
Operational:
TX Power status change
Cold start
Fronthaul Port Status Change
Node Shutdown
Channel Frequency Change
RU Parameter Change
Environmental:
Node Voltage out-of-range condition
Node Temperature out-of-range condition
The RU generates high-temperature, low-temperature, and shutdown temperature alarms, which report
to the EM S.
Synchronization:
Sync status changes (fail, not locked, or out-of-sync, disabled)
Node Synchronization Lock Status Changed
Node Internal Clock Status Change
Node PTP M aster/ Slave Status Change
Access:
RU Local Access Attempt
Table 3
ORAN
Item Specification
Synchronization The RU supports the following standards:
Telecom Slave Clock (T-TSC) to" G8275.1", "G8275.2" and Assisted Partial Timing Support. RU provides
additional noise filtering to filter front-haul interface dynamic noise, which helps to meet 3GPP frequency
accuracy requirement
Additional noise filtering to filter front-haul interface dynamic noise, which helps to meet 3GPP frequency
accuracy requirement
M aintains sync holdover with SyncE, in case of GPS or IEEE 1588 loss for 24 hours
G.8275.1 synchronization
IEEE 1914.1, ITU-T G.826x, G.827x series
Able connect to a DU on site located remotely in a data center as far as 200 microseconds away
Internet Protocol Supports IPv4 and IPv6
RU Hardware Feature
RU Specifications
22
Release 1.0 · Issue 1, March 2021
Fujitsu and Fujitsu Customer Use Only