7.1
RU Alarms
The RU detects and report s the alarms as described in the following tables. The details of crit ical, major, and
minor alarms are subject to change.
Table 34
Unit out of order
Probable Cause Severity Corrective Action
RU is broken/ abnormal operation
Note: Stops all RF transmission
Critical Reset
Table 35
Soft alarm
Probable Cause Severity Corrective Action
Soft ware on RU is operat ing abnormally Critical Reset
Table 36
Initialization failure
Probable Cause Severity Corrective Action
Soft ware on RU is operat ing abnormally
Note: Stops all RF transmission
Critical Reset
Table 37
IQ over Input
Probable Cause Severity Corrective Action
IQ over Input ALM
(n71/ n29/ n26, Port#A to #D)
Note: Stops RF transmission at alarm
occurring port
M ajor Reset