Table 5 (Cont.)
Specification In 3GPP 38.113
Phenomenon Application Reference Standard
Detail
Specification
Criteria
Electrostatic discharge Enclosure IEC 61000-4-2 Electric Discharge B
Fast transients common mode Signal, telecommunications and
control ports, DC power input
ports
IEC 61000-4-4 Fast Transients
Common Mode
B
RF common mode 0,15…80 MHz Signal, telecommunications and
control ports, DC power input
ports
IEC 61000-4-6 RF Common Mode A
Surges, common and differential
mode
AC power input ports,
telecommunications port
IEC 61000-4-5 Resistability of
Lightning
B
Radiated Immunity
Test Standard 3GPP 38.113
IEC 61000-4-3 Level 3
Test mode Traffic mode, no test in RX exclusion band
80…6000 M Hz 3 V/ m, AM 80%
Performance Criteria A
Electric Discharge
Test standard 3GPP 38.113
IEC 61000-4-2
Contact discharge ±4 kV
Air discharge ±8 kV
Performance Criteria B
Fast Transients Common Mode
Test standard 3GPP 38.113
IEC 61000-4-4
0.5 kV
Performance criteria B
Injected port Power port, RET Port