User's Guide

Enter Setup
** Exit Setup
80
Set Length Range for Code 128
The scanner can be configured to only decode Code 128 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.
Set the Minimum Length (Default: 1)
Set the Maximum Length (Default: 48)
If minimum length is set to be greater than maximum length, the scanner only decodes Code 128
barcodeswitheithertheminimumormaximumlength.Ifminimumlengthissameasmaximumlength, only
Code 128 barcodes with that length are to bedecoded.
Set the scanner to decode Code 128 barcodes containing between 8 and12 characters:
1.
Scan the Enter Setup barcode.
2.
Scan the Set the Minimum Lengthbarcode.
3.
Scan the numeric barcode “8” from the “Digit Barcodes” section inAppendix.
4.
Scan the Save barcode from the “Save/Cancel Barcodes” section inAppendix.
5.
Scan the Set the Maximum Lengthbarcode.
6.
Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section inAppendix.
7.
Scan the Save barcode from the “Save/Cancel Barcodes” section inAppendix.
8.
Scan the Exit Setup barcode.